The effects of poloxamer and sodium alginate mixture (Guardix-SG®) on range of motion after axillary lymph node dissection: A single-center, prospective, randomized, double-blind pilot study.

Division of Breast Surgery, Department of Surgery, University of Ulsan College of Medicine, Asan Medical Center, Seoul, Korea. Department of Rehabilitation Medicine, University of Ulsan College of Medicine, Asan Medical Center, Seoul, Korea. Division of Breast Surgery, Department of Surgery, Ulsan University Hospital, Ulsan, Korea. Department of Surgery, Inje University Ilsan Paik Hospital, Goyang-si, Gyeonggi-do, Korea. Division of Breast Surgery, Department of Surgery, Dongnam institute of Radiological and medical science, Busan, Korea. Division of Breast Surgery, Department of Surgery, Kosin University Gospel Hospital, Busan, Korea. Department of Clinical Epidemiology and Biostatistics, Asan Medical Center, Seoul, Korea.

PloS one. 2020;(9):e0238284

Abstract

PURPOSE Restricted shoulder mobility is a major upper extremity dysfunction associated with lower quality of life and disability after breast cancer surgery. We hypothesized that a poloxamer and sodium alginate mixture (Guardix-SG®) applied after axillary lymph node dissection (ALND) would significantly improve shoulder range of motion (ROM) in patients with breast cancer. METHODS We conducted a double-blind, randomized, prospective study to evaluate the clinical efficacy and safety of Guardix-SG® for the prevention of upper extremity dysfunction after ALND. The primary outcome measure was shoulder ROM at baseline (T0) and 3 (T1), 6 (T2), and 12 months (T3) after surgery. Secondary outcome measures were the Disabilities of the Arm, Shoulder, and Hand score(DASH), pain associated with movement, which was assessed using a numeric rating scale, and lymphedema assessed using body composition analyzer. RESULTS A total of 83 women with breast cancer were randomly assigned to either the Guardix-SG® group or the control group. In the Guardix-SG® group (n = 37), Guardix-SG® was applied to the axillary region after ALND. In the control group (n = 46), ALND was performed without using Guardix-SG®. Comparing ROM for shoulder flexion before surgery (178.2°) and 12 months after surgery (172.3°), that was restored 12 months after surgery in the Guardix-SG® group, and there was no statistically significant difference between that at before surgery and 12 months after surgery (p = 0.182). No adverse effect was observed in either group. CONCLUSIONS The results of this study have shown that Guardix-SG® help improve shoulder ROM without causing adverse effects in patients who underwent breast cancer surgery. However, there was no statistically significant difference from the control group. A further large-scale study is needed to obtain a more conclusive conclusion. TRIAL REGISTRATION CRISKCT0003386; https://cris.nih.go.kr (20181207).

Methodological quality

Metadata